Sump pump on a power station: runtime and what can start it
A sump pump needs a big start burst and runs only when the pit fills. Runtime depends on how often it runs, so we ask you for that number.
Check this in the calculatorSump pump 1/3 hp, 24 hours (planning duty) Flood-critical. Do not rely on one power station alone. Add a water-level alarm and a second backup (a battery-backed pump or a second station). Check the setup before storm season, not during.
The numbers
|
1/3 hp |
1/2 hp |
| Running watts (typical) |
800 W (range 500 to 800) |
1,050 W (range 800 to 1,050) |
| Start watts we test against |
1,600 W (high end of 1,000 to 1,600) |
2,150 W (high end of 1,300 to 2,150) |
| Energy at 5% duty (assumption) |
about 0.96 kWh/day |
about 1.26 kWh/day |
- These are generator-maker chart values, generic. Your pump’s nameplate beats them. Watts = volts x amps on the plate.
- The pass/fail table uses the high-end start value, so a pass has headroom.
- Many 1/2 hp pumps need more than 1,050 W continuous. A station under about 1,100 W continuous will fail the check.
How often does it run? You tell us.
The 5% duty (about 72 minutes a day) is our planning assumption for heavy rain, not a measurement. Runtime depends on pit size, inflow and how high the water is pumped. One logged pump ran about 30 seconds per cycle.
- In the calculator, enter minutes per day, or cycles per hour (we assume about 30 s per cycle).
- Count your own: time a few cycles during rain.
Motor start and the models we cannot confirm
Bluetti Elite 200 V2, Bluetti Elite 300, Anker SOLIX C1000 and Bluetti Elite 100 V2 do not publish a motor-start rating for this kind of load. They show motor start unverified: they pass on continuous watts only. Where the margin is within 50 W of a rating we mark it unconfirmed. Test the pump on the unit before a storm.
Cord and setup rules
- Use a heavy-duty outdoor-rated extension cord sized for the pump’s amps. A thin cord adds heat and voltage drop.
- Plug the pump in directly. Do not daisy-chain adapters.
- Keep the station dry and off the basement floor, above any possible water line.
- Check that the discharge hose and check valve work before you depend on backup.
Which models pass for a 1/3 hp sump pump
Setup: Sump pump 1/3 hp, 24 hours (planning duty). Sump pump, 1/3 hp, 800 W avg (24 h/day).
| Model | Wh | Runtime | Result | Price (checked on) |
| Bluetti Elite 30 V2 | 288 Wh | about 4 h | No too many watts ✗ continuous 800/600 W · ✗ start 1600/600 (no motor rating) W motor start unverified | $299.99 2026-11-21 |
| EcoFlow RIVER 3 Plus | 286 Wh | about 5 h | No too many watts ✗ continuous 800/600 W · ✗ start 1600/1200 W | $279 2026-11-02 (stale) |
| Jackery Explorer 240 v2 Sold out | 256 Wh | about 4 h | No too many watts ✗ continuous 800/300 W · ✗ start 1600/600 W | $249 2026-11-21 |
| Bluetti Elite 100 V2 | 1024 Wh | about 14.5 h | No not enough Wh ✓ continuous 800/1800 W · ? start 1600/1800 (no motor rating) W motor start unverified | $449.99 2026-11-21 |
| Jackery Explorer 1000 v2 Sold out | 1024 Wh | about 14 h | No not enough Wh ✓ continuous 800/1500 W · ✓ start 1600/3000 W | $559 2026-11-21 |
| EcoFlow DELTA 3 Plus Preorder | 1024 Wh | about 14.5 h | No not enough Wh ✓ continuous 800/1800 W · ✓ start 1600/3600 W | $719 2026-11-21 |
| Anker SOLIX C1000 | 1056 Wh | about 16.5 h | No not enough Wh ✓ continuous 800/1800 W · ? start 1600/1800 (no motor rating) W motor start unverified | $499.99 2026-11-21 |
| Anker SOLIX C1000 Gen 2 Preorder | 1024 Wh | about 15 h | No not enough Wh ✓ continuous 800/2000 W · ✓ start 1600/3000 W | $469.99 2026-11-21 |
| Jackery Explorer 1500 v2 | 1536 Wh | about 20 h | No idle draw eats the runtime ✓ continuous 800/2000 W · ✓ start 1600/4000 W | $949 2026-11-21 |
| Jackery Explorer 2000 v2 | 2042 Wh | about 28 h | Fits ✓ continuous 800/2200 W · ✓ start 1600/4400 W | $999 2026-11-21 |
| Bluetti Elite 200 V2 | 2074 Wh | about 31.5 h | Fits ✓ continuous 800/2600 W · ? start 1600/2600 (no motor rating) W motor start unverified | $899 2026-11-21 |
| Anker SOLIX C2000 Gen 2 Preorder | 2048 Wh | about 28.5 h | Fits ✓ continuous 800/2400 W · ✓ start 1600/4000 W | $849.99 2026-11-21 |
| Bluetti Elite 300 | 3014 Wh | about 43.5 h | Fits ✓ continuous 800/2400 W · ? start 1600/2400 (no motor rating) W motor start unverified | $1,099 2026-11-21 |
| EcoFlow DELTA Pro 3 Sold out | 4096 Wh | about 45.5 h | Fits ✓ continuous 800/4000 W · ✓ start 1600/8000 W | $2,799 2026-11-21 |
| Goal Zero Yeti 1500X Discontinued | 1516 Wh | about 22.5 h | No idle draw eats the runtime ✓ continuous 800/2000 W · ✓ start 1600/3500 W | $1,124.89 2026-11-21 |
Typical, editable figures, not measured. 90% usable depth, 85% inverter efficiency, plus idle draw. Method.
Updated 2026-11-21 (draft)